{"id":6166,"date":"2016-10-31T07:43:43","date_gmt":"2016-10-31T07:43:43","guid":{"rendered":"https:\/\/jurmed.ro\/medici\/?p=6166"},"modified":"2016-10-31T08:41:42","modified_gmt":"2016-10-31T08:41:42","slug":"reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala","status":"publish","type":"post","link":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/","title":{"rendered":"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103?"},"content":{"rendered":"<p style=\"text-align: justify;\">Rezultatele monitoriz\u0103rii dozimetrice individuale sunt folosite \u00een mai multe scopuri: pentru demonstrarea faptului c\u0103 sunt respectate cerin\u021bele legale cu privire la limitele de doz\u0103 primite de persoanele expuse profesional, reasigur\u0103 personalul c\u0103 m\u0103surile de radioprotec\u0163ie sunt eficiente \u0219i, nu \u00een ultimul r\u00e2nd, trebuie s\u0103 asigure un feedback cu privire la tipul practicii \u0219i riscul asociat acesteia.<\/p>\n<p style=\"text-align: justify;\">\u00cen \u021bara noastr\u0103, principalul tip de monitorizare dozimetric\u0103 individual\u0103 este reprezentat de <strong>dozimetria la nivelul \u00eentregului organism<\/strong>. Doza la nivelul \u00eentregului organism se evalueaz\u0103 folosind un dozimetru individual care se poart\u0103 la piept, sub \u0219or\u021bul de protec\u021bie, pentru toat\u0103 perioada desf\u0103\u0219ur\u0103rii de activit\u0103\u021bi \u00een c\u00e2mp de radia\u0163ii.<\/p>\n<p style=\"text-align: justify;\">\u00cen ultimii ani, o aten\u021bie sporit\u0103 a fost acordat\u0103 faptului c\u0103 exist\u0103 numeroase situa\u021bii, mai ales \u00een medicin\u0103, unde vorbim despre expuneri localizate doar pe anumite p\u0103r\u021bi ale corpului. Despre dozele primite \u00een aceste expuneri localizate, dozimetrul individual purtat sub \u0219or\u021b nu ne ofer\u0103 nicio informa\u021bie. De ce? Pentru c\u0103:<\/p>\n<ul style=\"text-align: justify;\">\n<li>\u015eor\u021bul plumbat reduce doza primit\u0103 de dozimetrul purtat sub \u0219or\u021b cu p\u00e2n\u0103 la 90%.<\/li>\n<li>Dozimetrul purtat sub \u0219or\u021bul de protec\u021bie m\u0103soar\u0103 doza primit\u0103 doar de zonele protejate ale corpului.<\/li>\n<li>\u00cen radiologie \/ cardiologie interven\u0163ional\u0103 este expus \u00een mod preponderent cristalinul persoanei expuse profesional, iar dozimetrul purtat sub \u0219or\u021b nu are cum s\u0103 ofere informa\u021bii despre doza la cristalin.<\/li>\n<li>\u00cen medicin\u0103 nuclear\u0103, extremit\u0103\u021bile sunt expuse, iar contribu\u021bia principal\u0103 la valoarea dozei este dat\u0103 de radia\u0163iile beta emise de radioizotopii utiliza\u021bi \u00een medicin\u0103. Este important de precizat c\u0103 radia\u0163iile beta cu energii mai mici de 700 keV contribuie doar la doza la nivelul pielii (de aceea doza la piele \/ extremit\u0103\u021bi se m\u0103soar\u0103 cu ajutorul m\u0103rimii Hp(0,07), adic\u0103 echivalentul de doz\u0103 la o ad\u00e2ncime de 0,07 mm) \u0219i nu aduc nicio contribu\u021bie la doza la nivelul \u00eentregului organism (care se m\u0103soar\u0103 la o ad\u00e2ncime de 10 mm, cu ajutorul m\u0103rimii Hp(10).<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">Studii europene recente [1] au ar\u0103tat c\u0103 \u00een expunerile localizate pot fi dep\u0103\u0219ite limitele admise, f\u0103r\u0103 ca limita dozei la nivelul \u00eentregului organism s\u0103 fie dep\u0103\u0219it\u0103. Spre exemplu, <strong>\u00een cazul medicilor care lucreaz\u0103 \u00een chirurgie interven\u0163ional\u0103, cardiologie sau medicin\u0103 nuclear\u0103, cele mai expuse zone sunt<\/strong> <strong>cristalinul \u015fi extremit\u0103\u0163ile<\/strong>, iar \u00een <strong>medicin\u0103 nuclear\u0103 extremit\u0103\u021bile sunt expuse la doze mari<\/strong>, ce pot dep\u0103\u0219i limitele de doz\u0103 impuse.<\/p>\n<p style=\"text-align: justify;\">Determinarea nivelelor de doz\u0103 la cristalin \u0219i extremit\u0103\u021bi \u00een cazurile expunerilor localizate a fost de interes crescut \u00een ultimii ani \u0219i, ca urmare a concluziilor rezultate din aceste studii, \u00een <strong>Directiva European\u0103\u00a0 nr. 59\/2013\/Euratom <\/strong>au ap\u0103rut<strong> modific\u0103ri legislative importante, <\/strong>dintre care cea mai important\u0103 este sc\u0103derea limitei dozei echivalente la cristalin <strong>de la 150 mSv\/an la 20 mSv\/an. <\/strong>Directiva 59\/EURATOM va fi preluat\u0103 \u00een legisla\u0163ia na\u0163ional\u0103 p\u00e2n\u0103 \u00een februarie 2018.<\/p>\n<p style=\"text-align: justify;\">Acest lucru va conduce la schimb\u0103ri majore \u00een modul \u00een care se va face monitorizarea dozimetric\u0103 individual\u0103. Un prim pas \u00een acest proces \u00eel constituie identificarea corect\u0103 a persoanelor expuse care vor avea nevoie de monitorizarea dozelor la cristalin \u015fi extremit\u0103\u021bi.<\/p>\n<p style=\"text-align: justify;\"><strong><u>Dozimetria la nivelul \u00eentregului organism<\/u><\/strong><\/p>\n<p style=\"text-align: justify;\">\u00cen toate domeniile de activitate, doza la nivelul \u00eentregului organism prezint\u0103 tendin\u021ba de sc\u0103dere, ca urmare a optimiz\u0103rii m\u0103surilor de protec\u021bie \u0219i a performan\u021belor echipamentelor radiologice folosite \u00een prezent. Recomand\u0103rile europene recente [2] aduc \u00een aten\u021bie nevoia de <strong>\u201cdouble dosimetry\u201d<\/strong> \u00een situa\u021bia \u00een care se poart\u0103 \u0219or\u021b de protec\u021bie. \u0218or\u021bul de protec\u021bie protejeaz\u0103 principalele organe ale corpului uman, dar nu acoper\u0103 \u00een \u00eentregime corpul, ceea ce \u00eenseamn\u0103 c\u0103 dozimetrul purtat sub \u0219or\u021b subevalueaz\u0103 doza la nivelul \u00eentregului organism, deoarece m\u0103soar\u0103 doza primit\u0103 de zonele protejate. Recomand\u0103rile cer purtarea unui dozimetru suplimentar, peste \u0219or\u021bul de protec\u021bie, pentru cunoa\u0219terea dozelor primite de zonele neprotejate ale corpului. Doza la nivelul \u00eentregului organism se calculeaz\u0103 lu\u00e2nd \u00een considerare informa\u021biile furnizate de dozimetrele purtate sub \u0219or\u021b \u0219i peste \u0219or\u021b.<\/p>\n<p style=\"text-align: justify;\">Un aspect important al utiliz\u0103rii unui dozimetru suplimentar purtat peste \u0219or\u021b, \u00een zona gulerului de tiroid\u0103, \u00eel constituie faptul c\u0103 va fi un indicator privind doza primit\u0103 de cristalin. De\u0219i dozimetrul whole-body purtat la gulerul de tiroid\u0103 nu va evalua cu acurate\u021be doza la nivelul cristalinului, el constituie un prim pas \u00een direc\u021bia cunoa\u0219terii nivelelor de doz\u0103 la cristalin, \u00eendeplinind simultan dou\u0103 cerin\u021be:<\/p>\n<ul style=\"text-align: justify;\">\n<li>o mai bun\u0103 evaluare a dozei la nivelul \u00eentregului organism, prin care se iau \u00een calcul \u0219i zonele neprotejate ale corpului<\/li>\n<li>un indicator pentru doza primit\u0103 de cristalin<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><strong><u>Dozimetria la cristalin<\/u><\/strong><\/p>\n<p style=\"text-align: justify;\">Cristalinul este unul din cele mai radiosensibile \u0163esuturi din organism. La ora actual\u0103, dozimetria la cristalin este un subiect de interes ridicat, deoarece studiile epidemiologice au ar\u0103tat <strong>cre\u0219terea inciden\u021bei cazurilor de cataract\u0103<\/strong> pentru persoanele expuse profesional care lucreaz\u0103 \u00een radiologia\/cardiologia interven\u0163ional\u0103. Profesioni\u015ftii din camerele \u00een care se practic\u0103 radiologia interven\u0163ional\u0103 (staff-ul medical \u015fi paramedical) petrec l\u00e2ng\u0103 sursa de radia\u0163ii X timp \u00eendelungat, mai multe ore pe zi, \u00een timpul procedurilor medicale. <strong>Riscul de apari\u0163ie a cataractei radioinduse<\/strong> este mare dac\u0103 nu sunt folosite metode de radioprotec\u0163ie. Doza la cristalin se m\u0103soar\u0103 folosind un detector purtat deasupra ochilor, pe o benti\u021b\u0103 ajustabil\u0103.<\/p>\n<p style=\"text-align: justify;\"><strong>\u00cen ce domenii este necesar\u0103 monitorizarea la cristalin?<\/strong><\/p>\n<ul style=\"text-align: justify;\">\n<li>Radiologia interven\u0163ional\u0103<\/li>\n<li>Cardiologie interven\u0163ional\u0103<\/li>\n<li>Radioterapie<\/li>\n<li>Medicina nuclear\u0103<\/li>\n<li>Medicina veterinar\u0103<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><strong><u>Dozimetria la extremit\u0103\u0163i<\/u><\/strong><\/p>\n<p style=\"text-align: justify;\">Pe plan european, se <strong>recomand\u0103 determinarea dozelor la extremit\u0103\u021bi \u00een cazul activit\u0103\u021bilor din medicina nuclear\u0103 \u0219i din radiologia \/ cardiologia interven\u021bional\u0103<\/strong>. Se recomand\u0103 monitorizarea la extremit\u0103\u021bi prin <strong>purtarea unui inel<\/strong> ce con\u021bine un detector termoluminescent, la baza degetului ar\u0103t\u0103tor al m\u00e2inii non-dominante. \u00cen medicina nuclear\u0103, studiile au ar\u0103tat c\u0103 de la v\u00e2rful degetului \u015fi p\u00e2n\u0103 la \u00eencheietura m\u00e2inii doza scade de 20 ori, de aceea nu se recomand\u0103 purtarea unui dozimetru tip br\u0103\u021bar\u0103 [3].<\/p>\n<p style=\"text-align: justify;\">\n<p style=\"text-align: justify;\"><strong><u>Despre DOZIMED<\/u><\/strong><\/p>\n<p style=\"text-align: justify;\">DOZIMED este singurul laborator din Rom\u00e2nia care este membru cu drept de vot \u00een European Radiation Dosimetry Group (EURADOS), organiza\u021bia european\u0103 care contribuie la dezvoltarea tehnico-\u0219tiin\u021bific\u0103 a dozimetriei radia\u021biilor ionizante.<\/p>\n<p style=\"text-align: justify;\">Compania le ofer\u0103 persoanelor expuse profesional la radia\u021bii ionizante o gam\u0103 complet\u0103 de servicii de dozimetrie individual\u0103, fiind <strong>singurul laborator autorizat pentru toate tipurile de determin\u0103ri de doz\u0103 datorate expunerii profesionale<\/strong>: la nivelul \u00eentregului organism, la cristalin \u0219i la extremit\u0103\u021bi.<\/p>\n<p style=\"text-align: justify;\">DOZIMED ofer\u0103 servicii de monitorizare dozimetric\u0103 individual\u0103 pentru toate domeniile de activitate din domeniul nuclear: medicin\u0103, industrie, educa\u021bie, radioactivitate natural\u0103, cercetare nuclear\u0103.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline; color: #0000ff;\">http:\/\/www.dozimed.ro\/<\/span><\/p>\n<p style=\"text-align: justify;\"><strong>Bibliografie<\/strong><\/p>\n<ol style=\"text-align: justify;\">\n<li>ORAMED: Extremity and Eye lens dosimetry in interventional procedures, <a href=\"http:\/\/www.oramed-fp7.eu\/en\">http:\/\/www.oramed-fp7.eu\/en<\/a><\/li>\n<\/ol>\n<ol style=\"text-align: justify;\">\n<li>EC\/RP160 &#8211; &#8222;Technical recommendations for monitoring individuals occupationally exposed to external radiation&#8221;, Directorate General for Energy and Transport \u2014 Nuclear Energy, 2009<\/li>\n<\/ol>\n<ol start=\"3\">\n<li style=\"text-align: justify;\">ISO 15382:2015 \u2013 Radiation protection \u2013 Procedures for monitoring the dose to the lens of the eye, the skin and the extremities<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Rezultatele monitoriz\u0103rii dozimetrice individuale sunt folosite \u00een mai multe scopuri: pentru demonstrarea faptului c\u0103 sunt respectate cerin\u021bele legale cu privire la limitele de doz\u0103 primite de persoanele expuse profesional, reasigur\u0103 [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":6167,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"footnotes":""},"categories":[81,578],"tags":[579],"class_list":["post-6166","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cardiologie","category-radiologie-si-radioterapie","tag-dozimed"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103? - Jurmed - Medici<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/\" \/>\n<meta property=\"og:locale\" content=\"ro_RO\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103? - Jurmed - Medici\" \/>\n<meta property=\"og:description\" content=\"Rezultatele monitoriz\u0103rii dozimetrice individuale sunt folosite \u00een mai multe scopuri: pentru demonstrarea faptului c\u0103 sunt respectate cerin\u021bele legale cu privire la limitele de doz\u0103 primite de persoanele expuse profesional, reasigur\u0103 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/\" \/>\n<meta property=\"og:site_name\" content=\"Jurmed - Medici\" \/>\n<meta property=\"article:published_time\" content=\"2016-10-31T07:43:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-10-31T08:41:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3508\" \/>\n\t<meta property=\"og:image:height\" content=\"2480\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"costelv\" \/>\n<meta name=\"twitter:label1\" content=\"Scris de\" \/>\n\t<meta name=\"twitter:data1\" content=\"costelv\" \/>\n\t<meta name=\"twitter:label2\" content=\"Timp estimat pentru citire\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/\"},\"author\":{\"name\":\"costelv\",\"@id\":\"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/d32bd0fe3243bb12082045e5e5635d2d\"},\"headline\":\"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103?\",\"datePublished\":\"2016-10-31T07:43:43+00:00\",\"dateModified\":\"2016-10-31T08:41:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/\"},\"wordCount\":1166,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg\",\"keywords\":[\"Dozimed\"],\"articleSection\":[\"Cardiologie\",\"Radiologie si Radioterapie\"],\"inLanguage\":\"ro-RO\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/\",\"url\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/\",\"name\":\"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103? - Jurmed - Medici\",\"isPartOf\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg\",\"datePublished\":\"2016-10-31T07:43:43+00:00\",\"dateModified\":\"2016-10-31T08:41:42+00:00\",\"author\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/d32bd0fe3243bb12082045e5e5635d2d\"},\"breadcrumb\":{\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#breadcrumb\"},\"inLanguage\":\"ro-RO\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage\",\"url\":\"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg\",\"contentUrl\":\"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg\",\"width\":3508,\"height\":2480},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/jurmed.ro\/medici\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/jurmed.ro\/medici\/#website\",\"url\":\"https:\/\/jurmed.ro\/medici\/\",\"name\":\"Jurmed - Medici\",\"description\":\"JURMED \u2013 Jurnal de Sanatate este o publicatie lunara de informare si preventie medicala. Revista si site-ul au un continut bogat de articole si informatii cu adresabilitate catre publicul larg.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/jurmed.ro\/medici\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ro-RO\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/d32bd0fe3243bb12082045e5e5635d2d\",\"name\":\"costelv\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/562bbd538aef9094eff6466c34ed9504fe82c1cb144e421d853e80c3b3d5a9f8?s=96&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/562bbd538aef9094eff6466c34ed9504fe82c1cb144e421d853e80c3b3d5a9f8?s=96&r=g\",\"caption\":\"costelv\"},\"url\":\"https:\/\/jurmed.ro\/medici\/author\/costelvoicu\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103? - Jurmed - Medici","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/","og_locale":"ro_RO","og_type":"article","og_title":"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103? - Jurmed - Medici","og_description":"Rezultatele monitoriz\u0103rii dozimetrice individuale sunt folosite \u00een mai multe scopuri: pentru demonstrarea faptului c\u0103 sunt respectate cerin\u021bele legale cu privire la limitele de doz\u0103 primite de persoanele expuse profesional, reasigur\u0103 [&hellip;]","og_url":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/","og_site_name":"Jurmed - Medici","article_published_time":"2016-10-31T07:43:43+00:00","article_modified_time":"2016-10-31T08:41:42+00:00","og_image":[{"width":3508,"height":2480,"url":"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg","type":"image\/jpeg"}],"author":"costelv","twitter_misc":{"Scris de":"costelv","Timp estimat pentru citire":"6 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#article","isPartOf":{"@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/"},"author":{"name":"costelv","@id":"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/d32bd0fe3243bb12082045e5e5635d2d"},"headline":"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103?","datePublished":"2016-10-31T07:43:43+00:00","dateModified":"2016-10-31T08:41:42+00:00","mainEntityOfPage":{"@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/"},"wordCount":1166,"commentCount":0,"image":{"@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage"},"thumbnailUrl":"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg","keywords":["Dozimed"],"articleSection":["Cardiologie","Radiologie si Radioterapie"],"inLanguage":"ro-RO","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/","url":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/","name":"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103? - Jurmed - Medici","isPartOf":{"@id":"https:\/\/jurmed.ro\/medici\/#website"},"primaryImageOfPage":{"@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage"},"image":{"@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage"},"thumbnailUrl":"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg","datePublished":"2016-10-31T07:43:43+00:00","dateModified":"2016-10-31T08:41:42+00:00","author":{"@id":"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/d32bd0fe3243bb12082045e5e5635d2d"},"breadcrumb":{"@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#breadcrumb"},"inLanguage":"ro-RO","potentialAction":[{"@type":"ReadAction","target":["https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/"]}]},{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#primaryimage","url":"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg","contentUrl":"https:\/\/jurmed.ro\/medici\/wp-content\/uploads\/sites\/2\/2016\/10\/Dozimed-logo.jpg","width":3508,"height":2480},{"@type":"BreadcrumbList","@id":"https:\/\/jurmed.ro\/medici\/reprezinta-rezultatele-monitorizarii-individuale-un-feedback-corect-cu-privire-la-expunerea-profesionala\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/jurmed.ro\/medici\/"},{"@type":"ListItem","position":2,"name":"Reprezint\u0103 rezultatele monitoriz\u0103rii individuale un feedback corect cu privire la expunerea profesional\u0103?"}]},{"@type":"WebSite","@id":"https:\/\/jurmed.ro\/medici\/#website","url":"https:\/\/jurmed.ro\/medici\/","name":"Jurmed - Medici","description":"JURMED \u2013 Jurnal de Sanatate este o publicatie lunara de informare si preventie medicala. Revista si site-ul au un continut bogat de articole si informatii cu adresabilitate catre publicul larg.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/jurmed.ro\/medici\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ro-RO"},{"@type":"Person","@id":"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/d32bd0fe3243bb12082045e5e5635d2d","name":"costelv","image":{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/jurmed.ro\/medici\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/562bbd538aef9094eff6466c34ed9504fe82c1cb144e421d853e80c3b3d5a9f8?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/562bbd538aef9094eff6466c34ed9504fe82c1cb144e421d853e80c3b3d5a9f8?s=96&r=g","caption":"costelv"},"url":"https:\/\/jurmed.ro\/medici\/author\/costelvoicu\/"}]}},"_links":{"self":[{"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/posts\/6166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/comments?post=6166"}],"version-history":[{"count":7,"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/posts\/6166\/revisions"}],"predecessor-version":[{"id":6175,"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/posts\/6166\/revisions\/6175"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/media\/6167"}],"wp:attachment":[{"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/media?parent=6166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/categories?post=6166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jurmed.ro\/medici\/wp-json\/wp\/v2\/tags?post=6166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}